SUN-8/10/12K-SG04LP3-EU

8-12kW | Three Phase | 2 MPPT | Hybrid Inverter | LV Battery Supported

SUN-8/10/12K-SG04LP3-EU is brand new three phase hybrid inverter with low battery voltage 48V, ensuring system safe and reliable. With compact design and high-power density, this series supports 1.3 DC/AC ratio, saving device investment. It supports three phase unbalanced output, extending the application scenarios. Equipped with CAN port (x2) BMS and parallel, x1 RS485 port for BMS, x1 RS232 port for remotely control, x1 DRM port, which makes the system smart and flexible.

  • 100% unbalanced output, each phase; Max. output up to 50% rated power
  • AC couple to retrofifit existing solar system
  • Max. 10 pcs parallel for on-grid and off-grid
  • operation; Support multiple batteries parallel
  • Max. charging/discharging current of 240A
  • Support storing energy from diesel generator
  • 48V low voltage battery, transformer isolation design
  • 6 time periods for battery charging/discharging

 

Need Help? Let’s Get in Touch

Description

 

 

Product Specification

Model SUN-8K-SG04LP3-EU SUN-10K-SG04LP3-EU SUN-12K-SG04LP3-EU
Battery Input Data
Battery Type Lead-acid or Lithium-ion Lead-acid or Lithium-ion Lead-acid or Lithium-ion
Battery Voltage Range (V) 40~60 40~60 40~60
Max. Charging Current (A) 190 210 240
Max. Discharging Current (A) 190 210 240
Charging Curve 3 Stages / Equalization 3 Stages / Equalization 3 Stages / Equalization
External Temperature Sensor Yes Yes Yes
Charging Strategy for Li-Ion Battery Self-adaption to BMS Self-adaption to BMS Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W) 10400 13000 15600
Rated DC Input Voltage (V) 550 (160~800) 550 (160~800) 550 (160~800)
Start-up Voltage (V) 160 160 160
MPPT Range (V) 200-650 200-650 200-650
Full Load DC Voltage Range (V) 350-650 350-650 350-650
PV Input Current (A) 13+13 26+13 26+13
Max. PV ISC (A) 17+17 34+17 34+17
No. of MPP Trackers 2 2 2
No. of Strings per MPP Tracker 1+1 2+1 2+1
AC Output Data
Rated AC Output Active Power (W) 8000 10000 12000
Max. AC Output Active Power (W) 8800 11000 13200
AC Output Rated Current (A) 12.1/11.6 15.2/14.5 18.2/17.4
Max. AC Output Current (A) 13.4/12.8 16.7/15.9 20/19.1
Max. Three Phase Unbalanced Output Current (A) 18.2/17.4 22.7/21.7 27.3/26.1
Max. AC Current (A) 75 75 75
Max. Continuous AC Passthrough (A) 45 45 45
Peak Power (off grid) 2 time of rated power, 10 S 2 time of rated power, 10 S 2 time of rated power, 10 S
Power Factor Adjustment Range 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/380, 230/400 Vac 220/380, 230/400 Vac 220/380, 230/400 Vac
Rated Input/Output Grid Frequency/Range 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz
Grid Connection Form 3L/N/PE 3L/N/PE 3L/N/PE
Total Harmonics Current Distortion (THDi) <3% (of nominal power) <3% (of nominal power) <3% (of nominal power)
DC Current Injection <0.5% In <0.5% In <0.5% In
Efficiency
Max. Efficiency 97.60% 97.60% 97.60%
Euro Efficiency 97.00% 97.00% 97.00%
MPPT Efficiency 99.90% 99.90% 99.90%
Protection
Integrated Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge Protection(DC Type III/AC Type III) Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge Protection(DC Type III/AC Type III) Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge Protection(DC Type III/AC Type III)
Over Voltage Category DC Type II/AC Type III DC Type II/AC Type III DC Type II/AC Type III
Certifications and Standards
Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety EMC / Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating -40 to +60℃, >45℃ Derating -40 to +60℃, >45℃ Derating
Cooling Smart Cooling Smart Cooling Smart Cooling
Noise (dB) ≤45 dB ≤45 dB ≤45 dB
Communication with BMS RS485; CAN RS485; CAN RS485; CAN
Weight (kg) 33.6 33.6 33.6
Cabinet Size (W × H × D mm) 422 × 702 × 281 (Excluding Connectors and Brackets) 422 × 702 × 281 (Excluding Connectors and Brackets) 422 × 702 × 281 (Excluding Connectors and Brackets)
Protection Degree IP65 IP65 IP65
Installation Style Wall-mounted Wall-mounted Wall-mounted
Warranty 5 Years 5 Years 5 Years

 